The RTZM Medium-Current Lighting Busway 63-400A is designed for low-voltage lighting and end power distribution applications that require reliable electrical performance, flexible installation and convenient maintenance. With a rated working current of 63A to 400A and a rated working voltage of 230/400V, this lighting busway system is suitable for data center end power supply, indoor power distribution projects and other project-based electrical installations.
As a professional lighting busway manufacturer and supplier, ZHERUTONG provides configurable busway sections, plug-in units, feeder boxes and direction-change units to support different project layouts. The system adopts a large phase spacing design to support insulation performance, while its simple structure helps reduce installation complexity and makes on-site adjustment more convenient.
For data center and intelligent power distribution applications, the RTZM medium-current lighting busway can be configured with temperature monitoring and full electrical parameter monitoring systems according to project requirements. Plug-in units and feeder boxes can also support RS485 bus solutions and Modbus protocol, helping customers integrate the busway system with power and environmental monitoring platforms.
This product is suitable for B2B projects that require stable power distribution, modular installation, customized busway lengths and flexible tap-off configurations. Contact ZHERUTONG with your required current rating, layout drawings, straight length requirements, tap-off positions and monitoring needs for product selection and project quotation.
The RTZM medium-current lighting busway adopts a large phase spacing design to support the insulation capacity of the system. This structure helps maintain safe phase clearance and stable electrical performance in low-voltage power distribution applications.
The system is designed with a simple and practical structure, making it easier to install, maintain and adjust on site. This is especially useful for project environments where the busway layout, tap-off points or installation conditions may need to be adapted during implementation.
The busway adopts a single arm bolt locking design, helping improve installation efficiency and connection stability between busway units. This design supports faster assembly while maintaining reliable mechanical connection.
The unique non-reversible design helps prevent incorrect connection between busbar units during installation. This reduces the risk of installation errors and supports safer system assembly.
A unit connection expansion gap is designed between busway sections to help reduce the effect of linear expansion. This supports the electrical conductivity and mechanical strength of the overall busway system.
The aluminum alloy profile housing is compact, lightweight and easy to install. It provides sufficient strength to support and protect the bus duct system, helps avoid mechanical damage and supports good electrical continuity.
The non-magnetic housing material helps avoid eddy current effects, while the aluminum alloy structure supports heat dissipation and helps reduce temperature rise during operation. The housing also provides corrosion resistance for long-term use in suitable indoor environments.
The insulation materials inside the busway are selected to support heat resistance, insulation performance, mechanical strength and anti-aging ability. The safety distance and creepage distance between internal phases are designed to support stable electrical performance.
For data center end power distribution, the busway can be configured with temperature monitoring and full electrical parameter monitoring systems according to customer requirements. Plug-in units and feeder boxes can support RS485 bus solutions and Modbus protocol for integration with power and environmental monitoring systems.
The RTZM Medium-Current Lighting Busway 63-400A is available in multiple rated current options for low-voltage power distribution projects. The following electrical characteristics help engineers evaluate resistance, reactance, impedance, voltage loss, rated voltage, insulation performance and withstand capacity during product selection.
| Rated Current (A) | Resistance R20 (mΩ/m) | Reactance X20 (mΩ/m) | Impedance Z20 (mΩ/m) | Voltage Loss 0.6 (V/m) | Voltage Loss 0.7 (V/m) | Voltage Loss 0.8 (V/m) | Voltage Loss 0.9 (V/m) | Voltage Loss 0.95 (V/m) | Voltage Loss 1.0 (V/m) |
|---|---|---|---|---|---|---|---|---|---|
| 63 | 0.764 | 0.384 | 0.855 | 0.084 | 0.088 | 0.092 | 0.093 | 0.092 | 0.083 |
| 80 | 0.764 | 0.384 | 0.855 | 0.106 | 0.112 | 0.117 | 0.118 | 0.117 | 0.106 |
| 100 | 0.637 | 0.320 | 0.713 | 0.111 | 0.117 | 0.121 | 0.123 | 0.122 | 0.110 |
| 160 | 0.458 | 0.230 | 0.513 | 0.127 | 0.135 | 0.140 | 0.142 | 0.141 | 0.127 |
| 200 | 0.382 | 0.192 | 0.428 | 0.133 | 0.140 | 0.146 | 0.148 | 0.146 | 0.132 |
| 250 | 0.306 | 0.154 | 0.342 | 0.133 | 0.140 | 0.146 | 0.148 | 0.146 | 0.132 |
| 315 | 0.255 | 0.128 | 0.285 | 0.139 | 0.147 | 0.153 | 0.155 | 0.154 | 0.139 |
| 400 | 0.191 | 0.096 | 0.214 | 0.133 | 0.140 | 0.146 | 0.148 | 0.146 | 0.132 |
| Rated Current (A) | Rated Voltage AC | Rated Insulation Voltage (VAC) | Frequency f/Hz | Overall Dimension (mm) | Protection Degree | Short-Time Withstand Current Icw/kA | Peak Withstand Current Ip/kA | Insulation Resistance MΩ |
|---|---|---|---|---|---|---|---|---|
| 63 | 230/400 | 800 | 50/60 | 100×50 | 55 | 10 | 17 | 500 |
| 80 | 230/400 | 800 | 50/60 | 100×50 | 55 | 10 | 17 | 500 |
| 100 | 230/400 | 800 | 50/60 | 100×50 | 55 | 10 | 17 | 500 |
| 160 | 230/400 | 800 | 50/60 | 100×60 | 55 | 10 | 17 | 500 |
| 200 | 230/400 | 800 | 50/60 | 100×60 | 55 | 10 | 17 | 500 |
| 250 | 230/400 | 800 | 50/60 | 100×60 | 55 | 10 | 17 | 500 |
| 315 | 230/400 | 800 | 50/60 | 100×70 | 55 | 10 | 17 | 500 |
| 400 | 230/400 | 800 | 50/60 | 100×80 | 55 | 10 | 17 | 500 |
The straight length is the main power distribution section of the RTZM medium-current lighting busway system. It supports standard and customized lengths to match different project layouts.
| Item | Specification |
|---|---|
| Standard Lengths | 3000mm, 2000mm, 1000mm |
| Custom Lengths | 300mm to 3000mm |
| Tap-Off Openings | Minimum spacing 0.4m |
| Tap-Off Configuration | Single-sided or double-sided configurations available |
The plug-in unit is used to tap power from the busway system and supply connected loads. It supports flexible component configuration according to project requirements.
| Item | Specification |
|---|---|
| Rated Current | 10A to 200A |
| Component Configuration | Circuit breakers, fused switches and other components can be configured according to customer requirements |
| Cable Outlet Options | Power can be supplied via industrial sockets or cables routed through cable glands |
| Dimensions | External dimensions vary based on current rating and internal configuration |
| Monitoring Option | Electrical parameter monitoring modules can be configured for data center applications |
For data center applications, tap-off boxes can be equipped with comprehensive electrical parameter monitoring modules, supporting RS485 bus solutions and Modbus protocol for integration with power and environmental monitoring systems.
The flange end box is used for cable transition from the power supply end to the busway system. It can be configured according to current rating, component requirements and project installation conditions.
| Item | Specification |
|---|---|
| Main Function | Cable transition from power supply end to busway |
| Component Options | Circuit breakers and fused switches can be configured according to customer requirements |
| Dimensions | External dimensions depend on current rating and configuration |
| Monitoring Option | Full electrical parameter monitoring modules can be configured for data center applications |
When used in data center scenarios, the feeder box can be equipped with a comprehensive electrical parameter monitoring module, supporting RS485 bus solutions and Modbus protocol for integration with power and environmental monitoring systems.
Direction-change units help adapt the busway layout to actual site conditions. Only part of the elbow range is displayed; configurations can be flexibly adapted to specific on-site requirements.
| Unit Type | Function |
|---|---|
| Horizontal Bend | Supports horizontal direction change |
| Vertical Bend | Supports vertical direction change |
| T-Type Bend | Supports branch distribution layout |
The RTZM medium-current lighting busway system should be installed according to approved installation drawings, selected busway sections, connectors and related accessories.
During installation, the confirmed short busway section should be positioned on the pre-mounted support brackets. The connector bolts are loosened first, and the connector is then attached to the busway.
The next busway section is installed on the pre-mounted support brackets on the other side of the connector. During alignment, the N-phase should follow the same-side principle. After the busway alignment is adjusted, the connector bolts are tightened with a wrench.
After the connector is secured, the upper and lower joint cover plates are installed and fastened with bolts. This installation structure supports project-based assembly and helps simplify future maintenance or layout adjustment.
The RTZM Medium-Current Lighting Busway 63-400A is suitable for indoor low-voltage power distribution projects requiring modular installation, flexible tap-off points and convenient maintenance.
Typical applications include:
Data center end power distribution
Indoor lighting power distribution
Commercial building electrical distribution
Industrial facility power distribution
Project-based busway layouts requiring plug-in units
Electrical distribution systems requiring monitoring options
For data center applications, the system can be configured with temperature monitoring and full electrical parameter monitoring to support operation and maintenance management.
ZHERUTONG provides technical resources for busway and busbar trunking systems, including product specifications, technical datasheets and installation manuals. These resources support engineering design, project planning, equipment selection and installation review.
Available technical resources include:
ZHERUTONG RT-CMC Compact Busway Product Manual
ZHERUTONG Busway Trunking Series Product Technical Manual
Introduction to ZHERUTONG Busway Manufacturing Base
For accurate product selection, please provide project drawings, required current rating, busway layout, straight length requirements, tap-off positions, plug-in unit configuration and monitoring requirements.
A: The RTZM Medium-Current Lighting Busway is available from 63A to 400A, with current ratings including 63A, 80A, 100A, 160A, 200A, 250A, 315A and 400A.
A: The rated working voltage is AC 230/400V, and the rated insulation voltage is 800VAC.
A: Yes. This lighting busway can be used for end power distribution in data center applications. It can also be configured with temperature monitoring and full electrical parameter monitoring according to project requirements.
A: Yes. Standard straight lengths include 3000mm, 2000mm and 1000mm. Custom lengths from 300mm to 3000mm are available according to project layout requirements.
A: The minimum spacing for tap-off openings is 0.4m. Single-sided and double-sided tap-off configurations are available.
A: The plug-in unit is available from 10A to 200A. The configuration can be adjusted according to current rating, component selection and project requirements.
A: Plug-in units can be configured with circuit breakers, fused switches and other components according to customer requirements. Power can be supplied through industrial sockets or cables routed through cable glands.
A: For data center applications, plug-in units and feeder boxes can be equipped with electrical parameter monitoring modules, supporting RS485 bus solutions and Modbus protocol for integration with power and environmental monitoring systems.
A: Please provide the required current rating, rated voltage, busway layout drawings, straight length requirements, tap-off positions, plug-in unit configuration, feeder box requirements, monitoring needs and installation environment.
ZHERUTONG supplies medium-current lighting busway systems for B2B power distribution projects requiring reliable electrical performance, modular installation and configurable tap-off solutions.
To request a quotation, please send your project drawings, required current rating, straight length requirements, tap-off positions, plug-in unit configuration and monitoring requirements. Our team will review the project information and provide suitable product selection and quotation support.